3,744 research outputs found

    Characterising and Testing Deep UV LEDs for Use in Space Applications

    Full text link
    Deep ultraviolet (DUV) light sources are used to neutralise isolated test masses in highly sensitive space-based gravitational experiments. An example is the LISA Pathfinder charge management system, which uses low-pressure mercury lamps. A future gravitational-wave observatory such as eLISA will use UV light-emitting diodes (UV LEDs), which offer numerous advantages over traditional discharge lamps. Such devices have limited space heritage but are are now available from a number of commercial suppliers. Here we report on a test campaign that was carried out to quantify the general properties of three types of commercially available UV LEDs and demonstrate their suitability for use in space. Testing included general electrical and UV output measurements, spectral stability, pulsed performance, temperature dependence as well as thermal vacuum, radiation and vibration survivability

    Testing modified gravity with globular cluster velocity dispersions

    Full text link
    Globular clusters (GCs) in the Milky Way have characteristic velocity dispersions that are consistent with the predictions of Newtonian gravity, and may be at odds with Modified Newtonian Dynamics (MOND). We discuss a modified gravity (MOG) theory that successfully predicts galaxy rotation curves, galaxy cluster masses and velocity dispersions, lensing, and cosmological observations, yet produces predictions consistent with Newtonian theory for smaller systems, such as GCs. MOG produces velocity dispersion predictions for GCs that are independent of the distance from the galactic center, which may not be the case for MOND. New observations of distant GCs may produce strong criteria that can be used to distinguish between competing gravitational theories.Comment: 4 pages, 2 figures; accepted for publication in Ap

    Comparison of pre-emptive and reactive strategies to control an incursion of bluetongue virus serotype 1 to Great Britain by vaccination.

    Get PDF
    Bluetongue (BT) is a disease of ruminants caused by bluetongue virus (BTV), which is spread between its hosts by Culicoides midges. Vaccination is the most effective way to protect susceptible animals against BTV and was used reactively to control the recent northern European outbreak. To assess the consequences of using vaccination pre-emptively we used a stochastic, spatially explicit model to compare reactive and pre-emptive vaccination strategies against an incursion of BTV serotype 1 (BTV-1) into Great Britain. Both pre-emptive and reactive vaccination significantly reduced the number of affected farms and limited host morbidity and mortality. In addition, vaccinating prior to the introduction of disease reduced the probability of an outbreak occurring. Of the strategies simulated, widespread reactive vaccination resulted in the lowest levels of morbidity. The predicted effects of vaccination were found to be sensitive to vaccine efficacy but not to the choice of transmission kernel

    Vaccinia virus immune evasion: mechanisms, virulence and immunogenicity

    Get PDF
    Virus infection of mammalian cells is sensed by pattern recognition receptors and leads to an innate immune response that restricts virus replication and induces adaptive immunity. In response, viruses have evolved many countermeasures that enable them to replicate and be transmitted to new hosts, despite the host innate immune response. Poxviruses, such as vaccinia virus (VACV), have large DNA genomes and encode many proteins that are dedicated to host immune evasion. Some of these proteins are secreted from the infected cell, where they bind and neutralize complement factors, interferons, cytokines and chemokines. Other VACV proteins function inside cells to inhibit apoptosis or signalling pathways that lead to the production of interferons and pro-inflammatory cytokines and chemokines. In this review, these VACV immunomodulatory proteins are described and the potential to create more immunogenic VACV strains by manipulation of the gene encoding these proteins is discussed

    Improved Simulation of the Mass Charging for ASTROD I

    Full text link
    The electrostatic charging of the test mass in ASTROD I (Astrodynamical Space Test of Relativity using Optical Devices I) mission can affect the quality of the science data as a result of spurious Coulomb and Lorentz forces. To estimate the size of the resultant disturbances, credible predictions of charging rates and the charging noise are required. Using the GEANT4 software toolkit, we present a detailed Monte Carlo simulation of the ASTROD I test mass charging due to exposure of the spacecraft to galactic cosmic-ray (GCR) protons and alpha particles (3He, 4He) in the space environment. A positive charging rate of 33.3 e+/s at solar minimum is obtained. This figure reduces by 50% at solar maximum. Based on this charging rate and factoring in the contribution of minor cosmic-ray components, we calculate the acceleration noise and stiffness associated with charging. We conclude that the acceleration noise arising from Coulomb and Lorentz effects are well below the ASTROD I acceleration noise limit at 0.1 mHz both at solar minimum and maximum. The coherent Fourier components due to charging are investigated, it needs to be studied carefully in order to ensure that these do not compromise the quality of science data in the ASTROD I mission.Comment: 20 pages, 14 figures, submitted to International Journal of Modern Physics

    A prospective study of resuscitative outcomes at a downtown Greenville SC hospital using Connect Care versus CodeNet for cardiac arrest documentation

    Get PDF
    Our study was looks at the difference between 2 systems used to document cardiac arrests in a hospital setting. One is a new machine that is called CodeNet. This documentation device was compared to the documentation system at Saint Francis Hospital in downtown Greenville, SC. When the details of a cardiac arrest are recorded (e.g., time it began, how many shocks were given, and what interval the shocks were given), this information can be used to look for patterns that predict survival. This can hopefully be used to create new protocols that will increase the patient\u27s chance of survival. This is being accomplished through chart review (cardiac arrest sheet) of cardiopulmonary arrest for 12 months and data collected with the CodeNet from cardiac arrests that occur in theIntensive Care UnitandCritical Care Unit. More data is being collected, but the preliminary results seem to indicate that CodeNet isa much moreefficient way to document the details of a cardiac arrest

    A novel blood test for tuberculosis prevention and treatment

    Get PDF

    Characterization of disturbance sources for LISA: torsion pendulum results

    Full text link
    A torsion pendulum allows ground-based investigation of the purity of free-fall for the LISA test masses inside their capacitive position sensor. This paper presents recent improvements in our torsion pendulum facility that have both increased the pendulum sensitivity and allowed detailed characterization of several important sources of acceleration noise for the LISA test masses. We discuss here an improved upper limit on random force noise originating in the sensor. Additionally, we present new measurement techniques and preliminary results for characterizing the forces caused by the sensor's residual electrostatic fields, dielectric losses, residual spring-like coupling, and temperature gradients.Comment: 11 pages, 8 figures, accepted for publication Classical and Quantum Gravit
    corecore